CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999Subject: difference density ripples around Hg atoms From: Klemens Wild Klemens {- dot -} Wild {- at -} BZH {- dot -} UNI-HEIDELBERG {- dot -} DE Date: 2007-08-01 Dear friends of the Fourier transform, I am refining a structure with 2 adjacent Hg atoms bound to cysteines of different monomers in the crystal contacts, which means I need to refine them as well. While the structure nicely refines (2.2 A data), I do not get rid of negative density ripple layers next to them (-10 sigmas). My question: is this likely due to anistropy of the soft mercury atoms (anisotropic B refinement decreases the ripples) or is this likely a summation truncation effect prominent for heavy atoms? Can I just anistropically refine the mercuries while I keep the rest isotropic? Never saw this in a PDB. Suggestions are very welcome. Greetings Klemens Wild CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999 |
|