| Quick navigation: | Home | Site Map || References | Biography || Copyright | Other copyright | Contact us | Advert | | |
Re: [ccp4bb] pointless / batch number / axial hkl |
||
- Protein crystallographyMain steps:- Protein purification- Crystallisation Special:- Programs for crystallography- X-ray detectors Basic tutorials:- Chemistry- Protein - Peptide - Amino Acids Xtal community:- CCP4BB |
CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999Subject: Re: pointless / batch number / axial hkl From: Phil Evans pre {- at -} MRC-LMB {- dot -} CAM {- dot -} AC {- dot -} UK Date: 2007-08-31 On 31 Aug 2007, at 21:52, Bryan W. Lepore wrote: > [1] is there a way to make pointless read only up to a certain > batch number? > Not at present - I'll add it at some stage, it wouldn't be hard You can use "rebatch" to select batches > [2] should pointless compare axial reflections along all axes > regardless of input spacegroup? i.e, is it a waste of time to > permute axes when indexing? > > e.g, if pointless reports this : > Zone Number PeakHeight SD Probability > ReflectionCondition > 1 screw axis 4(2) [c] No observations > 1 screw axis 4(1) [c] No observations > 2 screw axis 2(1) [a] 28 0.969 0.291 *** 0.917 > h00: h=2n > > ... does that mean [b] was not inspected? > No this means that in pointgroup 422 [b] is equivalent to [a] It does check all necessary axes in each accepted point (Laue) group Phil CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999 |
|