| Quick navigation: | Home | Site Map || References | Biography || Copyright | Other copyright | Contact us | Advert | | |
Re: [ccp4bb] finicky protein / cell disruption |
||
- Protein crystallographyMain steps:- Protein purification- Crystallisation Special:- Programs for crystallography- X-ray detectors Basic tutorials:- Chemistry- Protein - Peptide - Amino Acids Xtal community:- CCP4BB |
CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999Subject: Re: finicky protein / cell disruption From: Thomas Earnest TNEarnest {- at -} LBL {- dot -} GOV Date: 2008-03-03 I will second this recommendation to use alternate cell disruption methods instead of sonication. Particularly with multi-protein complexes, where the preservation of the complex from disruption though crystallization is important, sonication can be quite deleterious. Even with the French press (or a cell emulsifier), disruption at low pressures (e.g. three passes at low pressure) increases the level integrity of full complexes, while giving good yield. My recommendation is to throw your sonicator away and use methods that apply less heat and energy to your cells and to your biomolecules. - Th Thomas Earnest, Ph.D. Senior Scientist and Group Leader Structural Proteomics Development Group Physical Biosciences Division MS64R0121 Lawrence Berkeley National Laboratory Berkeley CA 94720 TNEarnest@lbl.gov 510 486 4603 Mads Gabrielsen wrote: > I am not a big fan of sonication. Try changing your way of disrupting the > cells. > > I have compared sonication vs mechanical stress on several unrelated proteins, > and for me a good old french press wins every time. If you want to get all > modern and fancy, a cell disruptor gives similar results. > > Cheers, > > Mads Gabrielsen > > > [Hide Quoted Text] > > On Mar 2, 2008, at 11:47 PM, Tim Gruene wrote: > > Hi all > > sorry, for offtopic query... > > I am trying to purify my protein by Ni-NTA affinity chromatography. After > sonication as i centrifuge bacterial lysate, soon after 10 min whole > lysates > get precipitated during loading on the column and some time it remain > soluble too. if i get purified through the column without precipitation, > it > gets precipitated during dialysis. > I have tried lot, by chnaging buffers, increasing salt or deacreasing salt > or no salt at are helpless. > I do purifiaction in cold room. > > can any one suggest some solution? > > Thanks in advance. > > NSH > > > CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999 |
|
| ProteinCrystallography.org: Copyright 2006-2010 by Quid United Ltd |