Quick navigation:        Home   |    Site Map   ||    References   |    Biography   ||    Copyright   |    Other copyright   |    Contact us   |   
Protein structure
 

Re: [ccp4bb] Stop Refmac from refining B factors?

 

Basic tutorials:
 
 

CCP4bb navigation

CCP4bb <-- 2007 <-- April 2007 <-- 18 April 2007
Previous message:
Subject: Re: twin fraction varies between crystals?
From: Eleanor Dodson ccp4 {- at -} YSBL {- dot -} YORK {- dot -} AC {- dot -} UK
Date: 2007-04-18
Next message:
Subject: AW: Stop Refmac from refining B factors?
From: Herman {- dot -} Schreuder {- at -} SANOFI-AVENTIS {- dot -} COM Herman {- dot -} Schreuder {- at -} SANOFI-AVENTIS {- dot -} COM
Date: 2007-04-18


Subject: Re: Stop Refmac from refining B factors?
From: Eva Kirchner eva {- dot -} kirchner {- at -} UNI-TUEBINGEN {- dot -} DE
Date: 2007-04-18

Thank you both, Mischa and Harry, I'll try overall B refinement. But I'm
starting to think that my Refmac is somewhat crappy, I tried this before,
and then all the B-factors were exactly the same. Now, I tried it again and
they are not... Something's still wrong here.

(But I'm still curious about the B-factor refinement when there is no "REFI
BREF ISOT" in the com-file...)

Eva



2007/4/18, Mischa Machius :
>
> Like Harry said, it is not justified to do individual B factor refinement
> at that resolution. Well, you can do it, but you'll end up with funny
> results, such as what are observing right now. Still, from a pragmatic point
> of view, individual B factor refinement in cases like these can have a
> positive effect on the electron density. However, keep in mind that the
> resulting B factors may physically not be very meaningful. In the end,
> you'll have to switch to grouped B factor refinement, or you risk nasty
> comments from an attentive mentor or reviewer (and rightly so). Hope that
> helps. Best - MM
> On Apr 18, 2007, at 7:20 AM, Eva Kirchner wrote:
>
> Hi,
>
> I have a little problem with B-factor refinement. I'm using the CCP4i
> interface, Refmac 5.2.0019, a resolution of 30-3.2 A (I tried 8-3.2 A as
> well, it doesn't make a big difference for this problem), and a current
> Rfree of 30.4%.
>
> Refmac refines the B-factors so that they are nearly the same for main
> chain and side chain, and I don't like that (or could it make sense in any
> way?). Moreover, my structure is a protein complex, and Refmac is mainly
> doing this for one component of the complex. If I take the B-factors from
> the original uncomplexed protein (around 18, 1.75 A) and add 44 to them
> with moleman to get them in the range they are in the complex, Refmac
> "flattens" them remarkably in only 5 cycles of restricted refinement. Does
> anyone have an explanation for this? I am pretty sure that the complex
> components are in the right place, I see beautiful density and everything I
> should see at this resolution.
>
> Here is what I tried further:
>
> * I de-selected "Refine isotropic temperature factors" in the Refmac
> interface. There was no REFI BREF ISOT any more in the com file. But there
> was also no difference in the B-factors compared to when there _was_ REFI
> BREF ISOT in the com file... So does Refmac just _ignore_ my wish not to
> refine B-factors? (The REFI keywords were as follows: type REST - resi MLKF
> - meth CGMAT - is there any B-factor-thing hidden in this?)
>
> * I played around with the geometric parameters. If I select the B-factor
> values there (the keywords are TEMP
BFAC
> ), it does not make _any_ difference,
> what values I fill in there, the resulting B-factors are always the same
> (but different from when I don't use the TEMP keyword, and even "flatter").
> Default for WBSCAL is 1.0, I tried 10, 1.0, 0.1, 0.01, and the equivalent
> numbers for the sigbs.
>
> Thanks for any thoughts on this,
>
> Eva
>
>
>
>
> --------------------------------------------------------------------------------
> Mischa Machius, PhD
> Associate Professor
> UT Southwestern Medical Center at Dallas
> 5323 Harry Hines Blvd.; ND10.214A
> Dallas, TX 75390-8816; U.S.A.
> Tel: +1 214 645 6381
> Fax: +1 214 645 6353
>
>
>




ProteinCrystallography.org: Copyright 2006-2008 by Quid United Ltd