CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999Subject: Re: HKL2000 and incompleteness From: Wladek Minor wladek {- at -} IWONKA {- dot -} MED {- dot -} VIRGINIA {- dot -} EDU Date: 2009-04-11 Try to increase profile fitting radius. WM ------Original Message------ From: Ted Erickson Sender: CCP4 bulletin board To: CCP4BB@JISCMAIL.AC.UK ReplyTo: Ted Erickson Subject: Re: [ccp4bb] HKL2000 and incompleteness Sent: Apr 11, 2009 7:56 PM >So before I lose it because of HKL2000, I have two questions, and I'd appreciate any answers to either: >1. Can there be another reason for incompleteness that I am missing (other than blind region at higher res., overlaps, overloads, and "not enough many frames")? Another explanation for incompleteness could be due to crystal packing that results in an asymmetric diffraction pattern. The discrepancy between HKL2000 and mosflm maybe a result of the resolution cutoff, however, this is only a speculation. Ted www.P212121.com Sent via BlackBerry by AT&T CCP4bb navigationCCP4bb <-- 1999 <-- November 1999 <-- 30 November 1999 |
|